Example report 108 · Energy & utilities · Regression
Estimate household heating load
What is the predicted thermal energy required for residential heating next week?
Recommended by Impulse AI
Impulse AI result
Selected model: Impulse AI custom model
Standard algorithms and custom models are candidates within the Impulse AI workflow—not competing services.
- Illustrative test result · MAE
- 3.2 kwh
Optimize heat distribution grid loading
- Records
- 13,000 fictional building_unit records
- Training / test
- 10,400 / 2,600
- Metric
- MAE · lower is better
- Models evaluated
- 8
01The business question
What is the predicted thermal energy required for residential heating next week?
Each record represents one building_unit record. The target to predict is thermal_kwh.
What you would do with it
Optimize heat distribution grid loading
02The input data
- insulation_ratinginput
- total_floor_areainput
- window_surface_ratioinput
- ambient_daily_lowinput
- occupancy_hoursinput
- thermostat_setting_avginput
- thermal_kwhtarget
Group-held-out 80/20 split; repeated entities stay in the same partition.
03Models evaluated
This illustrative recommendation represents model selection on training/validation data. The separate test scores below show how the candidates compare; a real workflow must not use its final test set to choose a model. Lower is better for MAE.
| Candidate model | Test MAE (illustrative) |
|---|---|
| Impulse AI custom modelSelected by Impulse AI | 3.2 kwh |
| XGBoost | 3.744 kwh |
| CatBoost | 4.08 kwh |
| LightGBM | 4.416 kwh |
| Extra Trees | 4.752 kwh |
| Random Forest | 5.088 kwh |
| Ridge Regression | 5.424 kwh |
| Training-target meanbaseline | 5.76 kwh |
04Practical takeaway
In this fictional report, Impulse AI selects Impulse AI custom model, with an illustrative test result of 3.2 kwh, compared with 5.76 kwh for the Training-target mean baseline. Impulse AI’s role is to evaluate candidates and deliver the selected model, whether it uses a standard algorithm or a custom model. The prediction supports one decision: optimize heat distribution grid loading
05Limitations
- This is a fictional adaptation of the linked source’s theme, not a reproduction of its dataset or results. Inputs, sample sizes and scores are invented. Keep repeated entities together during evaluation, use only information available at prediction time, and validate on new sites and later dates before operational use. Model associations do not demonstrate causation or certify safety.
- All rows and scores are invented for illustration; a real table would need its own evaluation.
- A single test split gives one estimate; scores on new data will vary.
06Source of inspiration
Kaggle Datasets · Public catalog metadata; fictional thematic adaptation, not the original dataset or its results
House Sales in King County, USA(opens in new tab)The linked sources inspired this fictional problem; the report may simplify or adapt the original task. No source datasets were downloaded or evaluated, and no competition results were copied.
07Exploratory data profile
A compact illustrative profile of the 6 inputs, not the full checks a real engine run performs. 312 missing values appear across the table. All ranges are fictional.
| Column | Type | Valid | Missing | Missing % | Unique | Mean | Std dev | Min | 25% | Median | 75% | Max | Zeros % |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| insulation_rating | Numeric | 13,000 | 0 | 0.0% | 49 | 16.5 | 11 | 0 | 8.25 | 16.5 | 24.75 | 132 | 1.0% |
| total_floor_area | Numeric | 13,000 | 0 | 0.0% | 170 | 28.5 | 19 | 0 | 14.25 | 28.5 | 42.75 | 212 | 2.5% |
| window_surface_ratio | Numeric | 12,766 | 234 | 1.8% | 121 | 0.64 | 0.24 | 0 | 0.46 | 0.64 | 0.82 | 1 | 4.0% |
| ambient_daily_low | Numeric | 13,000 | 0 | 0.0% | 412 | 52.5 | 35 | 0 | 26.25 | 52.5 | 78.75 | 372 | 1.0% |
| occupancy_hours | Numeric | 12,922 | 78 | 0.6% | 533 | 64.5 | 43 | 0 | 32.25 | 64.5 | 96.75 | 452 | 2.5% |
| thermostat_setting_avg | Numeric | 13,000 | 0 | 0.0% | 654 | 76.5 | 51 | 0 | 38.25 | 76.5 | 114.75 | 532 | 4.0% |
08Use your model
Download model
Take a reusable model package to run predictions in your own environment.
Host for inference
Have Impulse AI host your model so you can send new data for predictions.
Related reports
- Energy & utilitiesTime Series
Forecast a building’s electricity demand
How much electricity will a property need over the next day?
predicts next_day_kwh
Open report - Energy & utilitiesRegression
Predict photovoltaic panel output
What is the anticipated energy generation for rooftop solar systems given local cloud cover?
predicts energy_mwh
Open report - Energy & utilitiesClassification
Identify high-risk weather impact events
Will weather conditions exceed equipment structural thresholds?
predicts is_threshold_exceeded
Open report