Skip to content

Example report 14 · Renewable energy · Time Series

Forecast solar power generation

How much electricity might a solar installation generate in its next operating window?

All examples

Recommended by Impulse AI

Impulse AI result

Selected model: XGBoost

Standard algorithms and custom models are candidates within the Impulse AI workflow—not competing services.

Illustrative test result · MAE
17.85 kWh

Prepare grid-balancing and storage plans around expected generation.

Records
5,160 fictional inverter windows
Training / test
4,128 / 1,032
Metric
MAE · lower is better
Models evaluated
8

01The business question

How much electricity might a solar installation generate in its next operating window?

Each record represents one inverter window. The target to predict is generated_kwh.

What you would do with it

Prepare grid-balancing and storage plans around expected generation.

02The input data

  • recent_generationinput
  • forecast_irradianceinput
  • module_temperature_cinput
  • ambient_temperature_cinput
  • inverter_capacity_kwinput
  • daylight_minutesinput
  • generated_kwhtarget

Chronological 80/20 split; all lagged inputs precede the forecast cutoff.

03Models evaluated

This illustrative recommendation represents model selection on training/validation data. The separate test scores below show how the candidates compare; a real workflow must not use its final test set to choose a model. Lower is better for MAE.

Candidates within the Impulse AI workflow; fictional test scores, not a ranking of competing services
Candidate modelTest MAE (illustrative)
XGBoostSelected by Impulse AI17.85 kWh
Impulse AI custom model18.4 kWh
CatBoost23.46 kWh
LightGBM25.39 kWh
ETS27.32 kWh
ARIMA29.26 kWh
Last value31.19 kWh
Seasonal naivebaseline33.12 kWh

04Practical takeaway

In this fictional report, Impulse AI selects XGBoost, with an illustrative test result of 17.85 kWh, compared with 33.12 kWh for the Seasonal naive baseline. Impulse AI’s role is to evaluate candidates and deliver the selected model, whether it uses a standard algorithm or a custom model. The prediction supports one decision: prepare grid-balancing and storage plans around expected generation.

05Limitations

  • Use forecast irradiance rather than future measured irradiance. A short monitoring history may miss seasonal changes and equipment outages.
  • All rows and scores are invented for illustration; a real table would need its own evaluation.
  • A single test split gives one estimate; scores on new data will vary.

06Source of inspiration

Kaggle Datasets · Dataset catalog; generation and sensor readings from two plants

Solar Power Generation Data(opens in new tab)

The linked sources inspired this fictional problem; the report may simplify or adapt the original task. No source datasets were downloaded or evaluated, and no competition results were copied.

07Exploratory data profile

A compact illustrative profile of the 6 inputs, not the full checks a real engine run performs. 124 missing values appear across the table. All ranges are fictional.

Illustrative column profile, fictional values
ColumnTypeValidMissingMissing %UniqueMeanStd devMin25%Median75%MaxZeros %
recent_generationNumeric5,16000.0%1210.640.2400.460.640.8211.0%
forecast_irradianceNumeric5,16000.0%20033.522.333016.7533.550.252522.5%
module_temperature_cNumeric5,067931.8%3211818-104.51831.5450.0%
ambient_temperature_cNumeric5,16000.0%4421818-104.51831.5450.0%
inverter_capacity_kwNumeric5,129310.6%56369.546.333034.7569.5104.254922.5%
daylight_minutesNumeric5,16000.0%68481.554.333040.7581.5122.255724.0%

08Use your model

Download model

Take a reusable model package to run predictions in your own environment.

Host for inference

Have Impulse AI host your model so you can send new data for predictions.